Silicone Drum Heater Band Performance 300-1500W | Fast Drum Heating 25-200 L

Silicone Drum Heater Band - Performance | 300-1500 W

fiber_manual_record In stock Delivery in 4-6 days
  • High-powered heating applied evenly across the band, to bring a drum up to temperature without hotspots
  • Straps directly onto a steel drum with a hook and spring — no jacket, no lid, fitted or moved in a minute
  • Capillary thermostat in its own control box on every band, adjustable 0–120 °C
  • Six sizes covering 25 L to 200 L drums, in 125 mm and 180 mm band widths
  • 230 V · 300–1500 W · IP40 · Class II double-insulated · 2 m HO7RN-F cable
€249.00
Tax excluded
Model
Quantity
Need more info?

icon-delivery.svg
Hassle-free delivery
Safely receive your product in days not weeks
prdt-icon-secure.svg
Secure transactions
SSL encrypted payment and data gateway
icon-returns.svg
Total satisfaction
Lightning-quick customer service with a 30-day refund policy

When a drum has to be emptied on a shift, heating time is the part of the job that holds everything else up. The Performance range puts high power into the drum wall and spreads it evenly across the full width of the band, so a cold drum of oil, wax or resin reaches pumping temperature quickly rather than over a night shift. It straps to the drum where the drum stands — no heating cabinet, no decanting, no lid.

The band is glass-fibre reinforced silicone with PFA-coated resistance wire laid widthways through it, which is what lets the power go up without burning a stripe into the product against the steel. A hook and spring hold it against the drum wall, and each band carries its own capillary thermostat and 2 m cable.

Purpose — heating time as the bottleneck

A drum that will not pour does not just cost the transfer; it costs the line waiting for it. Warming a 200 L drum through is slow work if the heat goes in gently, and moving drums into a heated room to thaw them overnight ties up floor space and handling for every drum in the queue.

Applying more power to the drum wall shortens that wait, provided the heat is spread rather than concentrated. That is the reason the wire runs widthways through the band: the same watts reach the steel over the whole band area instead of along a few lines of wire.

How it works in practice

Match the band to the drum diameter, hook it round the drum and let the spring pull it tight against the wall. The band must sit flat against bare steel — an air gap, a label ridge or a rolling hoop under the band all cost heat transfer and make the thermostat read the wrong thing. Set the thermostat to the temperature the product tolerates; the dial is the limit, and the band holds there rather than climbing past it.

On 200 L drums there is a choice worth understanding: the same 1000 W is available as a 125 mm band and as a 180 mm band. The wider band spreads that power over more drum wall, so the steel under it runs at a lower power density while the drum still reaches the same temperature. Where the same 180 mm band is specified at 1500 W, the extra power goes into reaching temperature faster.

One to three bands can run on the same drum, depending on drum size, fill level, product properties and the time available for heating. Fit each band where it sits flat against the steel and where there is product behind the drum wall.

Key features

  • High power density with even distribution — a drum reaches working temperature quickly without hotspots against the steel
  • PFA-coated resistance wire laid widthways — even heat across the band and a coating that survives the wear that shortens the life of cheaper bands
  • Two band widths on 200 L drums — 180 mm spreads the same power over more drum wall, 125 mm suits drums with less clear wall
  • Glass-fibre reinforced silicone body — stays flexible on the drum and tolerates repeated fitting and removal
  • Hook-and-spring fixing — one band fitted or moved in about a minute, with no tools and nothing left on the drum
  • Class II double-insulated with a 2 m HO7RN-F cable — plugs into a standard 230 V supply

Certification & Approvals

  • CE marked
  • IP40
  • Class II, double-insulated
  • Not ATEX rated — not for use in classified hazardous areas

Technical Specifications

  • Heating element: PFA-coated resistance wire
  • Body: glass-fibre reinforced silicone
  • Control: capillary thermostat, 0–120 °C
  • Voltage: 230 V
  • Power: 300–1500 W by size
  • Drum sizes: 25 L, 50 L, 105 L and 200 L
  • Band widths: 125 mm and 180 mm
  • Band lengths: 800, 940, 1300 and 1665 mm
  • IP rating: IP40
  • Power cable: 2 m HO7RN-F
  • Fixing: hook and spring

Applications

  • Bringing cold drums of oil, hydraulic fluid and lubricants to pumping temperature at the start of a shift
  • Melting waxes, fats and soaps that have set solid, where the drum is needed the same day
  • Reducing the viscosity of resins, adhesives and varnishes before mixing, spraying or dosing
  • Keeping a drum at working temperature through a production run
  • Drum stores and decanting stations where several drums are turned around in sequence

Operational Requirements

  • For steel drums. The hook-and-spring fixing and the heat transfer both depend on a rigid metal wall
  • The band must sit flat against the drum with no air gap behind it
  • Set the thermostat to the temperature the product tolerates — that setting is the limit, not the band
  • IP40: for indoor industrial use, not for washdown or wet locations
  • Industrial use only — to be operated by trained personnel familiar with heating-equipment safety
  • Not suitable for classified hazardous (ATEX) areas

Selection guidance

Performance is the range to choose when the drum has to be ready and the product tolerates being brought up at a normal industrial rate. Where the material benefits from a gentler warm-up, the Eco range applies less power per square centimetre over the same drum sizes. Where the setpoint itself has to be held accurately because overshooting would damage the product, the Digital range uses the same band with a digital thermostat. Underneath, all three are the same band: the same silicone, the same wire, the same fixing and the same cable.

Model Variants

The same band is available in two other ranges. The Eco range applies a lower power density, for products that benefit from a gentler warm-up, and the Digital range uses a digital thermostat, where the setpoint has to be held closely. Need a different drum heating principle altogether? See the full drum heater range.

HeatXperts
HXP-3110-PER

Data sheet

Length
800 mm.
Width
125 mm.
IP Class
IP40
Power rating
300 Watt
Temperature controller
Analogue
Temperature range
0 - 120°C
Voltage
230V
Compatible with
25-30 Liter drum
Drum compatible
Metal

Specific References

EAN13
0705808359731

You might also like