Outdoor Heating Mat - 150 W/m²
- 150 W/m² at 230 V — 1050, 1500 or 1800 W across 7, 10 or 12 m²
- Thaws frozen ground and keeps fresh concrete and mortar frost-free while they cure
- 50 cm wide, only 3,5 mm thin — rolls out on site and back up after the job
- IPX7 twin-conductor screened cable, Teflon-insulated and Kevlar-reinforced
- 2,5 m cold lead with Schuko plug as standard; other plugs on request
Frost stops a building site in three ways: frozen ground cannot be dug, fresh concrete and mortar must not freeze while they cure, and ice closes walkways and entrances. The Outdoor Heating Mat is rolled out directly over the area, covered with an insulating mat and plugged in, so the heat goes down into the ground or the structure instead of up into the cold air.
Each mat is 50 cm wide and delivers 150 W/m² at 230 V. It comes in three lengths — 14, 20 and 24 m — covering 7, 10 or 12 m². Larger areas are covered by laying several mats side by side, each on its own supply.
Purpose – Keeping winter work on schedule
Concrete that freezes before it has gained strength is damaged for good, and mortar in new brickwork behaves the same way. Frozen ground is just as hard on the programme: excavators struggle, foundations cannot be cast on frozen subsoil, and the crew waits for a thaw that may not come for weeks.
A heating mat moves the problem from the weather forecast to the site. It puts a steady 150 W/m² into the surface for as long as it is switched on, so frozen ground thaws where the mat lies and a fresh slab or wall is held above freezing while it cures.
How it works in practice
The mat is a twin-conductor heating cable woven into a carrier mesh. The mesh holds the cable at a fixed spacing, so the heat is spread evenly over the whole area rather than in stripes along the cable. Roll it out flat over the ground, slab or wall foot you need to heat, then lay the insulating mat on top and switch on.
The insulating mat is part of the system, not an optional extra. Without it, most of the heat escapes upwards into the air and the mat does not reach its stated output — with it, the heat is held down where the frost is. The insulating mat is ordered separately.
Because the cable is only 3,5 mm thick and sealed to IPX7, the mat lies flat under the insulation and tolerates melt water, wet soil and slush. After the job it is rolled up and moved to the next area.
Key features
- 150 W/m² surface output — an even heat over the full mat area
- Twin-conductor cable — connected from one end only, through a single cold lead
- Fully screened with a tinned copper earth screen — safe to use on wet ground and on site
- Teflon-insulated, Kevlar-reinforced heating wires — made for repeated use on site
- PVC outer sheath rated 90°C — takes the wear of a building site
- IPX7 — sealed against melt water, standing water and wet ground
- Fixed cable spacing in a carrier mesh — no hot or cold stripes across the area
Certification & Approvals
- CE marked
- Protection degree IPX7
Technical Specifications
- Nominal voltage: 230 VAC, 50 Hz
- Heat output: 150 W/m²
- Width: 500 mm
- Length: 14, 20 or 24 m
- Area covered: 7, 10 or 12 m²
- Power per mat: 1050, 1500 or 1800 W
- Thickness: 3,5 mm
- Cable construction: Twin-conductor, fully screened
- Heating element: Kevlar-reinforced
- Heating-wire insulation: Teflon
- Earth screen: Tinned copper, 1,5 mm²
- Outer sheath: PVC, 90°C
- Max. cable temperature: 80°C
- Cold lead: 2,5 m, 2 × 1,5 mm² + screen, 6,5 × 4,5 mm
- Plug: Schuko (CEE 7/7) as standard
- Protection degree: IPX7
Applications
- Thawing frozen ground before excavation, trenching and foundation work
- Keeping fresh concrete slabs and castings frost-free while they cure
- Frost protection of mortar in new brickwork and freshly built external walls
- Keeping walkways, ramps and site entrances free of ice
- Protecting germinating seed in horticulture and agriculture
Operational Requirements
Always lay an insulating mat over the heating mat. Without insulation the mat does not reach its stated output, and much of the energy is lost to the air.
Connect through an installation with an RCD. Installation must follow national wiring regulations and be carried out by an authorised electrician.
Never shorten the heating cable — only the cold lead may be shortened or extended.
Selection guidance
Choose the length from the area you need to heat: 14 m covers 7 m², 20 m covers 10 m² and 24 m covers 12 m². For larger or irregular areas, combine several mats side by side — each mat has its own cold lead and plug. Other plug types are available on request: CEE 16 A (blue, IEC 60309), UK (BS 1363), Swiss (SEV 1011), Danish and Australian.
Data sheet
- Heated Area
- 7,0 m²
- Cold Lead Length
- 2,5 meter
- Weight
- 3,3 kg
- Length
- 14 meter
- Width
- 500 mm.
- IP Class
- IPX7
- Power rating
- 1050 Watt
- Voltage
- 230V
- Approvals
- CE approved
- Plug
- Schuko (CEE 7/7)
- Thickness
- 3,5 mm