Jessberger JP-810.90 Air-Operated Diaphragm Pump ¾" — ATEX Zone 2 | PP / PVDF / ALU / AISI 316

Jessberger JP-810.90 Air-Operated Diaphragm Pump ¾" 100 l/min — ATEX Zone 2

fiber_manual_record In stock Delivery in 2-4 days
  • Air-operated double diaphragm (AODD) pump, ATEX Zone 2 certified — no electrical ignition source in the fluid zone
  • Four housing materials: PP, PVDF, ALU and AISI 316 — each with matched standard diaphragm and seal configuration
  • Flow up to 100 l/min, viscosity up to 25,000 mPas, passes solids to 4 mm — ¾" BSP connections
  • Self-priming to 9.8 m wet suction lift — runs dry without damage, no mechanical seal
  • Adjustable flow via air pressure (max. 8 bar) — requires no electrical supply or speed controller
€575.00
Tax excluded
Housing
Quantity
Need more info?

icon-delivery.svg
Hassle-free delivery
Safely receive your product in days not weeks
prdt-icon-secure.svg
Secure transactions
SSL encrypted payment and data gateway
icon-returns.svg
Total satisfaction
Lightning-quick customer service with a 30-day refund policy

The JP-810.90 is the first ¾" model in the JP-810 series — selected when volume requirements or viscosity exceed what ½" pipework can deliver. At 100 l/min and 25,000 mPas, it handles both high-volume transfer from IBCs and the thickest pumpable media in the series, making it the standard choice for sustained production-rate operations involving large drums, IBCs and tank emptying. Four housing materials are available: PP, PVDF, ALU and AISI 316, each paired with a matched internal configuration for diaphragm, ball valves and seats.

Purpose

The AODD operating principle means compressed air alternates between two chambers, driving a pair of flexible diaphragms back and forth. No electric motor contacts the fluid zone — making the JP-810.90 inherently safe for flammable and explosive media classified for ATEX Zone 2. The pump is fully self-priming, can run dry without damage and handles media containing suspended solids up to 4 mm. For applications involving high-viscosity media that require pre-heating before transfer, the pump pairs well with a HeatXperts drum heater to reduce viscosity to pumpable levels. Where stricter Zone 1 certification is required, the JP-810.90 Conductive version with carbon-filled housing is available as a separate product.

Selecting your housing

Housing selection determines chemical compatibility and dictates the standard internal configuration. PP is the all-round choice for acids, alkalis and most aqueous media — the standard configuration pairs a Hytrel diaphragm with PTFE balls and PP seats. PVDF handles highly aggressive media including strong oxidising acids and halogenated solvents that would compromise PP — the standard configuration uses a Santoprene/PTFE composite diaphragm with PTFE balls and PVDF seats. ALU (aluminium) is suited to solvents, fuels, oils and non-aqueous hydrocarbons — the standard configuration uses an NBR/Santoprene diaphragm with stainless steel seats. AISI 316 stainless steel covers highly corrosive aqueous media, strong acids and alkalis that attack aluminium, and food or pharmaceutical process fluids — the standard configuration pairs a Hytrel/PTFE composite diaphragm with PTFE balls and stainless steel seats. Contact us for configuration advice specific to your medium and operating conditions.

Key features

  • AODD operating principle — no electrical components in the fluid path, inherently safe for flammable media
  • Dry-running capable — no mechanical seal, no damage if air supply continues with empty chamber
  • Self-priming — pulls liquid from 5 m dry or 9.8 m wet suction lift without manual priming
  • Passes solids to 4 mm — ball-check valve design tolerates particulate media
  • Adjustable flow and delivery head via inlet air pressure — no frequency inverter required
  • Non-lubricated air operation — no oil separator required in the air supply line
  • Separable manifold — allows two different media to be pumped simultaneously
  • Easy field maintenance — modular design, standardised spare parts kit available
  • Available in PP, PVDF, ALU and AISI 316 housing — matched diaphragm and seal configuration per material

Certification & Approvals

  • ATEX Zone 2 gas: II 3/3 G Ex h IIC T4 Gb
  • ATEX Zone 2 dust: II 3 D Ex h IIIB T 135°C Db X
  • CE marked

Technical Specifications

  • Drive: compressed air (non-lubricated)
  • Air connection: 3/8" BSP
  • Max. air pressure: 8 bar
  • Fluid connection: ¾" BSP
  • Max. flow rate: 100 l/min
  • Max. delivery head: 80 m
  • Suction lift (dry): 5 m
  • Suction lift (wet): 9.8 m
  • Max. solid passing: 4 mm
  • Max. viscosity: 25,000 mPas
  • Stroke volume: 200 cm³
  • Noise level: 72 dB (at max. air pressure)
  • Housing materials: PP, PVDF, ALU, AISI 316

JP-810.90 performance curve — flow rate vs. delivery head at varying air pressure

Typical media by housing

  • PP: dilute acids, alkalis, detergents, aqueous chemical solutions, water treatment chemicals
  • PVDF: concentrated acids, oxidising agents, halogenated solvents, aggressive cleaning agents
  • ALU: solvents, fuels, oils, hydrocarbons, non-aqueous media compatible with aluminium
  • AISI 316: highly corrosive acids and alkalis, aggressive aqueous media, food and pharmaceutical process fluids

Applications

  • IBC emptying (1,000L and above) in chemical, petrochemical and food production
  • High-volume drum filling and transfer lines requiring sustained output
  • Transfer of heavy resins, thick adhesives and polymers from large containers
  • Large-scale solvent and fuel transfer in production environments — ALU housing
  • Sustained-flow chemical supply to reactors, mixing vessels and storage tanks
  • Offshore and mining fluid handling where high output and ATEX Zone 2 certification are required

Operational Requirements

  • Air supply must be clean, dry and non-lubricated — do not use lubricated air (damages internal seals)
  • Inlet air pressure must not exceed 8 bar — operating above rated pressure reduces diaphragm life
  • Can be run dry without damage — no minimum flow requirement
  • Ensure fluid connection piping is adequately supported — do not use the pump housing as a pipe anchor
  • If the pump is stalled (air on, no flow), the diaphragm is under constant load — avoid prolonged stall conditions
  • Verify chemical compatibility for the specific medium and temperature before commissioning
  • Note: the PVDF product image shows the Conductive (black) version — the Standard PVDF pump is supplied in grey housing.

JP-810 Series — Other Sizes

JP-810.90

Data sheet

Approvals
CE approved
Viscosity
25.000 mPas
Flow rate (l/min)
100 l/min
Media
Oils
Explosion Proof (EX)
Yes
Industries
Water treatment
EX Temperature Class
T4
EX Zones
Zone 22 (Dust)
ATEX Marking
II 3/3 G Ex h IIC T4 Gb
Temperature range
-4°C to +65°C
Weight
5,1 kg
Dimensions
W 293 × D 179 × H 267 mm

Specific References

EAN13
0705808354088