Jessberger JP-810.20 Air-Operated Diaphragm Pump 3/8" — ATEX Zone 2 | PP / POM / PVDF / AISI 316

Jessberger JP-810.20 Air-Operated Diaphragm Pump 3/8" 20 l/min — ATEX Zone 2

fiber_manual_record In stock Delivery in 2-4 days
  • Air-operated double diaphragm (AODD) pump, ATEX Zone 2 certified — no electrical ignition source in the fluid zone
  • Four housing materials: PP, POM, PVDF and AISI 316 — each with matched standard diaphragm and seal configuration
  • Flow up to 20 l/min, viscosity up to 10,000 mPas, passes solids to 2.5 mm — 3/8" BSP connections
  • Self-priming to 9.8 m wet suction lift — runs dry without damage, no mechanical seal
  • Adjustable flow via air pressure (max. 7 bar) — requires no electrical supply or speed controller
€315.00
Tax excluded
Housing
Quantity
Need more info?

icon-delivery.svg
Hassle-free delivery
Safely receive your product in days not weeks
prdt-icon-secure.svg
Secure transactions
SSL encrypted payment and data gateway
icon-returns.svg
Total satisfaction
Lightning-quick customer service with a 30-day refund policy

The JP-810.20 is the only model in the JP-810 series available with POM housing — making it the first choice when food contact compliance, low extractables or compatibility with fuels, oils and alcohols requires more than PP. At 20 l/min and 3/8" BSP connections, it handles small-to-medium transfer volumes with precise flow control. Four housing materials are available: PP, POM, PVDF and AISI 316, covering dilute process chemicals through to concentrated acids and pharmaceutical-grade media.

Purpose

The AODD operating principle means compressed air alternates between two chambers, driving a pair of flexible diaphragms back and forth. No electric motor contacts the fluid zone — making the JP-810.20 inherently safe for flammable and explosive media classified for ATEX Zone 2. The pump is fully self-priming, can run dry without damage and handles media containing suspended solids up to 2.5 mm. For applications involving high-viscosity media that require pre-heating before transfer, the pump pairs well with a HeatXperts drum heater to reduce viscosity to pumpable levels. Where stricter Zone 1 certification is required, the JP-810.20 Conductive version with carbon-filled housing is available as a separate product.

Selecting your housing

Housing selection determines chemical compatibility and dictates the standard internal configuration. PP is the all-round choice for acids, alkalis and most aqueous media — the standard configuration pairs a Hytrel diaphragm with PTFE balls and PP seats. PVDF handles highly aggressive media including strong oxidising acids and halogenated solvents that would compromise PP — the standard configuration uses a Santoprene/PTFE composite diaphragm with PTFE balls and PVDF seats. POM (polyoxymethylene) offers good resistance to fuels, oils, hydrocarbons and alcohols where PP is not suitable — the standard configuration uses an NBR/PTFE diaphragm with PTFE balls and POM seats. AISI 316 stainless steel covers highly corrosive aqueous media, strong acids and alkalis, and process fluids in pharmaceutical and fine chemical applications — the standard configuration pairs a Hytrel/PTFE composite diaphragm with PTFE balls and stainless steel seats. Contact us for configuration advice specific to your medium and operating conditions.

Key features

  • AODD operating principle — no electrical components in the fluid path, inherently safe for flammable media
  • Dry-running capable — no mechanical seal, no damage if air supply continues with empty chamber
  • Self-priming — pulls liquid from 5 m dry or 9.8 m wet suction lift without manual priming
  • Passes solids to 2.5 mm — ball-check valve design tolerates particulate media
  • Adjustable flow and delivery head via inlet air pressure — no frequency inverter required
  • Non-lubricated air operation — no oil separator required in the air supply line
  • Separable manifold — allows two different media to be pumped simultaneously
  • Easy field maintenance — modular design, standardised spare parts kit available
  • Available in PP, POM, PVDF and AISI 316 housing — matched diaphragm and seal configuration per material

Certification & Approvals

  • ATEX Zone 2 gas: II 3/3 G Ex h IIC T4 Gb
  • ATEX Zone 2 dust: II 3 D Ex h IIIB T 135°C Db X
  • CE marked

Technical Specifications

  • Drive: compressed air (non-lubricated)
  • Air connection: 6 mm
  • Max. air pressure: 7 bar
  • Fluid connection: 3/8" BSP
  • Max. flow rate: 20 l/min
  • Max. delivery head: 70 m
  • Suction lift (dry): 5 m
  • Suction lift (wet): 9.8 m
  • Max. solid passing: 2.5 mm
  • Max. viscosity: 10,000 mPas
  • Stroke volume: 30 cm³
  • Noise level: 65 dB (at max. air pressure)
  • Housing materials: PP, POM, PVDF, AISI 316

JP-810.20 performance curve — flow rate vs. delivery head at varying air pressure

Typical media by housing

  • PP: dilute acids, alkalis, detergents, aqueous chemical solutions, water treatment chemicals
  • PVDF: concentrated acids, oxidising agents, halogenated solvents, aggressive cleaning agents
  • POM: fuels, oils, hydrocarbons, alcohols, non-aggressive solvents
  • AISI 316: highly corrosive acids and alkalis, aggressive aqueous media, pharmaceutical and fine chemical process fluids

Applications

  • Food-grade liquid transfer — oils, syrups and process fluids — POM or AISI 316 housing
  • Pharmaceutical process dosing and small-volume filling in ATEX Zone 2 environments
  • Transfer of fuels, oils, alcohols and non-aggressive solvents — POM housing
  • Dosing of inks, adhesives and coatings from small containers
  • Small-volume chemical transfer from 20–200L drums in laboratory and pilot-plant settings
  • Water treatment chemical dosing where precise, low-flow control is required

Operational Requirements

  • Air supply must be clean, dry and non-lubricated — do not use lubricated air (damages internal seals)
  • Inlet air pressure must not exceed 7 bar — operating above rated pressure reduces diaphragm life
  • Can be run dry without damage — no minimum flow requirement
  • Ensure fluid connection piping is adequately supported — do not use the pump housing as a pipe anchor
  • If the pump is stalled (air on, no flow), the diaphragm is under constant load — avoid prolonged stall conditions
  • Verify chemical compatibility for the specific medium and temperature before commissioning
  • Note: the PVDF product image shows the Conductive (black) version — the Standard PVDF pump is supplied in grey housing.

JP-810 Series — Other Sizes

JP-810.20

Data sheet

Approvals
CE approved
Viscosity
10.000 mPas
Flow rate (l/min)
20 l/min
Media
Oils
Explosion Proof (EX)
Yes
Industries
Chemical
EX Temperature Class
T4
EX Zones
Zone 22 (Dust)
ATEX Marking
II 3/3 G Ex h IIC T4 Gb
Temperature range
-4°C to +65°C
Weight
1,3 kg
Dimensions
W 147 × D 93 × H 170 mm

Specific References

EAN13
0705808353968